The Chicago Pneumatic CPS 900-150 JD is a single-stage, oil-injected, rotary screw type air compressor, powered by a John Deere liquid-cooled, six-cylinder turbocharged diesel engine.
The unit consists of an air end, diesel engine with exhaust treatment, cooling circuit, air/oil separation and control systems - all enclosed within a sound dampened powder coated steel enclosure.
A range of undercarriage formats, factory and locally installed options are available.
Special attention has been given to the overall product quality, user friendliness, ease of serviceability, and economical operation to ensure best in class cost of ownership.
Steel enclosure with very large doors for superior access, making maintenance easy.
Standard with 110% fluid containment and Tier 4 Final emissions the compressor is designed for use in all areas of the US and to meet stringent local site environmental concerns.
Special attention has been given to the overall product quality, user-friendliness, ease of serviceability, and economical operation to ensure best-in-class cost of ownership
SPECIFICATIONS
Model | CPS 900-150 JD | |
Minimum effective receiver pressure | Psi(g) | 58 |
Maximum effective receiver pressure |
Psi(g) | 175 |
Normal effective working pressure | Psi(g) | 150 - 100 |
Actual Free Air Delivery | cfm | 750 - 867 |
Compression stages | 1 | |
Approximate air outlet temperature, above ambient (standard air) | °F (°C) | Ambient +120 (49) |
Approximate air outlet temperature, above ambient (standard air) | °F (°C) | Ambient +20 (11) |
Air Compressor outlets | 1 x 2 "NPT & 2x 3/4" Chicago | |
Max. ambient temperature (at sea level) | °F (°C) | 120 (49) |
Maximum altitude | ft (m) | 14,000 (4,267) |
Minimum starting temperature (with cold weather options) | °F (°C) | -13 (-25) |
Air Receiver Capacity | Gal/Hr (L/Hr) | 16.7 (63.2) |
Compressor oil capacity | Gal/Hr (L/Hr) | 12.5 (47.5) |
Max Sound Pressure Level @ 23' (7m) at normal working speed & pressure |
dB(A) |
76 |
Engine | John Deere | 6068HFC08 |
Emissions Regulation | US EPA | Tier 4 Final |
Output at rated speed (@2100 rpm) | HP | 250 |
Number of Cylinders | 6 | |
Aspiration | Turbocharged | |
Displacement | cu in (L) | 415 (6.8) |
Engine speed (Unloaded) | rpm | 1300 |
Engine Speed (Maximum loaded) | rpm | 1850 - 2100 |
Engine oil capacity | US Gal (L) | 8.5 (32.2) |
Engine oil required | Low Ash Oil per API CJ-4, ACEA C9 | |
Engine coolant capacity | US Gal (L) | 11 (41.8) |
Fuel tank capacity | US Gal (L) | 88 (333) |
Fuel consumption at 0% | Gal/Hr (L/Hr) | 2.2 (8.3) |
Fuel consumption at 100% load | US Gal (L) |
10.1 (38.2) - 10.6 (40.2) |
Fuel type requires | Ultra Low slfer Diesel < 15 PPM (mg/KG) | |
DEF Consumption | Apx 3.5% of diesel consumption | |
DEF tank capacity | US Gal (L) |
11 (41.8) |
DEF Autonomy | ≥ 24 hours) | |
Alternator | A |
60 |
Battery Capacity (Cold Cranking Amps) | A | 2 @ 725 |
Compressor Element
The quality of a compressor can be measured through the reliability, efficiency and durability of the compressor element used. Through decades of expertise in the design of compressor elements, the result is the production of most efficient and reliable compressors in the market. When the screw element is efficient durability excels, maintenance intervals decrease and fuel consumption goes down.
The CPS 900-150 compressor utilizes a Chicago Pneumatic C146 element and is driven from the diesel engine.
Inlet air is filtered through a heavy duty two stage air filter.
Air/Oil Separator
Air and oil separation is achieved through a centrifugal oil separator combined with a filter element. Separators are ASME/CRN approved versions and are stamped accordingly.
Designed for a higher maximum working pressure, the separator is equipped with a sealed high pressure safety relief valve, sonic nozzle, automatic blow-down valve, and pressure regulator.
Cooling System
The cooling system consists of integrated side-by-side aluminum oil cooler with axial fan to ensure optimum cooling. The fan is protected by a guard for operator safety. There is an access port at the front of the machine for easy cleaning
The cooling system is suitably designed for continuous operation in ambient conditions up to 120°F, with canopy doors closed.
John Deere
John Deere 6068HFC08 Tier 4 Final, turbocharged, six-cylinder, liquid-cooled diesel engine provides ample power to operate the compressor continuously at full-load.
Meets all US EPA and Environment Canada exhaust legislations with Tier 4 Final compliance. The US EPA engine family is “FJDXL06.8302”
The engine utilizes a Diesel Particulate Filter (DPF) with active regeneration, a Diesel Oxidation Catalyst (DOC) and a Selective Catalytic Reduction (SCR) system to help meet Tier 4 Final emissions. All functionality of the engine and exhaust after treatment are controlledautomatically on the XC2003 controller.
Engine output at rated speed, in accordance to SAE Standard, is 250hp at 2100 rpm.The engine has the capability to start the compressor to -13°F (-25°C) with standard glow-plug aid, synthetic compressor oil and 120V blockheater.
The 88 Gal (333L) fuel tank is sufficiently sized to operate the unit for minimum of 8 hours at full-load condition. As well the unit requires Diesel Exhaust Fluid (DEF). There is a DEF tank sufficiently sized to operate the unit for a minimum of 24 hours.
Instrumentation
The John Deere 6068HFC08 after treatment consists of a Diesel Oxidization Catalyst (DOC), passive Diesel particulate Filter (DPF) and Selective Catalytic Reduction (SCR). The SCR utilizes the temperature of the exhaust to passively regenerate during normal use.